+86-13819126663

Electrode Humidifier Humidification Principle And Humidification Conditions

Apr 09, 2022

The working principle of the electrode humidifier: when the tap water enters the humidification barrel, the water level gradually rises. Electricity is applied to the electrodes of the humidifier. When the water level overflows the electrodes, a current loop is formed between the electrodes through the conductivity of the water, and the water is heated to boiling to output clean steam. With the steam output, the water level gradually decreases.


At this time, the water inlet valve is energized and opened, and water is supplied again until the appropriate water level is reached, and steam continues to be generated. When the concentration of minerals in the humidification barrel is getting higher and higher, the drain valve will automatically open to drain the waste water, and the humidifier will replenish new water again and continue the humidification process. Using tap water with too high or too low conductivity can cause the humidifier to wear out too quickly or not humidify enough.


Electrode humidifier operating conditions


1) Ambient temperature and humidity: host 5 ~ less than 85RH


2) The altitude of the installation site cannot exceed 2000M


3) The inclination between the installation surface and the vertical surface is greater than 5 degrees


4) Influent water quality: clean tap water and softened water replaced by non-industrial salt. The conductivity is 125~1250us/cm2, the water hardness is not more than 30 German degrees, otherwise a water purifier is installed; the inlet water temperature is 5~45 degrees.


5) Inlet water pressure: 0.1~0.5 M p a, interface size: DN15G1/2


Structural features of electrode humidifier


1. Intelligent control system


a, control system color SIEMENS controller: easy to operate, can adjust the humidification parameters arbitrarily. There are two types of control: switch value and proportional adjustment.


b. Proportional adjustment control board: The interface signal is: 0~10VDC, the humidification efficiency is 100%, and the humidification amount can be controlled within the range of 20~100%. That is, according to the different conductivity of water and the change of indoor humidity state, adjust the humidification ratio in time, control the amount of humidification, and keep the humidity constant within the set humidity range. The change of soluble mineral content (conductivity) automatically adjusts the drainage cycle in the humidification tank and prolongs the service life of the humidification tank.


2. Frame structure


a. Spray aluminum alloy frame: beautiful and impact-resistant.


b. Detachable galvanized spray panel: anti-scratch, flame retardant, anti-corrosion, anti-rust, arbitrary assembly, easy maintenance.


3. Fan (applicable to independent humidifier) The humidifier selects different types of brand-name fans according to the amount of humidification, with stable performance, reliable quality, low noise, low energy consumption, and continuous failure-free.


4. The original electrical parts are made of world famous brands ABB, SCHNEIDER and other companies, with good performance and reliable quality.


Electrode humidifier working characteristics


1. Humidification range: 1kg~126kg;


2. Fast humidification: it can meet various humidification requirements;


3. Clean and humidify: sterile, non-toxic, no white powder


Send Inquiry