Description
Wholesale Commercial Use 90L / D Portable Dehumidifier
Parameters
Model | CL-90H / 90L / D Portable Dehumidifier |
Humidity Removal | 90L/D |
Power Source | 220V-240V/50Hz/60Hz |
Rated Power Input | 1260W |
Certificate | CCC, CE, Rohs |
Circulating Air | 800M3/h |
Work Temperature | 5-38℃ |
Refrigerant | R410a |
Net Weight | 53Kg |
Gross Weight | 58Kg |
Applying Space | 80~120m2 |
Product Dimension | 460x595x830mm |
Packing Dimension | 490x625x860mm |
90L / D Portable Dehumidifier failures and solutions
1. The dehumidifier will stop quickly after being turned on, and it will take a long time to start again. The dehumidification effect is very poor.
Check the fault: (1) The wind speed of the tuyere is lower than the normal value; (2) The resistance value between the lead wires of the fan motor is measured with a multimeter, and it is found to be much lower than the normal value.
Maintenance method: According to the detection condition, it is judged that the winding of the wind turbine motor winding is short-circuited, which causes the fan speed to decrease and the air volume to decrease. Replace with a new fan motor and troubleshoot.
Analysis of the cause: The compressor of the dehumidifier is a rotary compressor, the heat resistance is poor, the fan motor speed is reduced, the air volume is reduced, that is, the air volume flowing through the condenser is reduced, causing the compressor discharge pressure to rise, resulting in compressor overheat protection ( Shutdown), the compressor overheating must be cooled down to a normal temperature after a long time of cooling, so the compressor can be restarted after waiting for a long time of cooling.