90L Office Use Dehumidifier failures and solutions
1, after the household dehumidifier used for two years, due to dirty plugging can not be dehumidified and repaired, and then used again, the same compressor and fan operating normally, but not dehumidification.
Check the fault: (1) The air filter and evaporator surface are very clean; (2) The working current of the compressor is different from that of the previous fault. The operating current is very large when the fault occurred last time. The refrigerant is seriously leaking.
Maintenance method: find leaks, repair, and troubleshooting.
Cause analysis: A large amount of refrigerant leaks. The displacement of the compressor is reduced, the load is small, and the operating current is changed.