+86-13819126663
Industrial Temperature Control Dehumidifier video

Industrial Temperature Control Dehumidifier

Micro-computer humidity setting, automatic induction, automatic control.

Description

Industrial Temperature Control Dehumidifier

Industrial Temperature Control DehumidifierIndustrial Temperature Control DehumidifierIndustrial Temperature Control DehumidifierIndustrial Temperature Control DehumidifierIndustrial Temperature Control Dehumidifier


Dehumidification mode of temperature control dehumidifier


(1) Cooling dehumidification mode


When the indoor temperature and humidity are relatively high, and the indoor cooling load is relatively large, the system operates in the cooling and dehumidifying mode. At this time, the four-way valve is not charged, the system operates according to the cooling mode, the second heat exchanger branch in the room is the electromagnetic valve is turned off, the outdoor heat exchanger is the condenser, and the indoor first heat exchanger is the evaporator. The indoor air is only cooled and dehumidified by the first heat exchanger in the room, and the air is returned to the room at a low temperature and low humidity. In this mode, the air volume or water volume of the outdoor heat exchanger can be adjusted to further adjust the cooling capacity and the dehumidification amount, and the cooling capacity and the dehumidification amount increase as the air volume or the water volume of the outdoor heat exchanger increases.


(2) Temperature and humidity dehumidification mode


When the indoor humidity and wet load are relatively high, and the indoor cooling load is relatively small, the system operates in the temperature and dehumidification mode. At this time, the four-way valve is not charged, the system is still operated in the cooling mode, the outdoor heat exchanger and the indoor second heat exchanger are two parallel condensers, and the indoor first heat exchanger is an evaporator. After the indoor air is cooled and dehumidified by the first heat exchanger in the room, it is reheated by partial condensation heat when passing through the second heat exchanger in the room, and the air is returned to the room. In this mode, the air volume and water volume of the outdoor heat exchanger can also be adjusted to adjust the distribution of the heat exchange amounts of the two condensers, and further control the indoor heat to achieve the purpose of controlling the indoor air temperature.


(3) Temperature rise and dehumidification mode


When the indoor humidity and wet load are relatively high, but the indoor temperature is low and the heat load is relatively small, the system operates in the temperature rising and dehumidifying mode. At this time, the four-way valve is not charged, the system operates according to the cooling mode, the outdoor heat exchanger branch is turned off by the electromagnetic valve, the second heat exchanger in the room is the condenser, and the indoor first heat exchanger is the evaporator. Since the high temperature refrigerant flows in the second heat exchanger 2 in the room, and the indoor air is cooled and dehumidified by the first heat exchanger in the room, the entire heat of condensation through the second heat exchanger in the room is used to reheat the air. In this mode, since the refrigerant flow path of the outdoor heat exchanger is turned off, the entire heat of condensation is taken up by the second heat exchanger in the room, and the heat of condensation of the system is greater than the heat of evaporation, so that the humidity of the treated air drops and the temperature rises.


(4) Heating mode


When the indoor temperature is very low and the heat load is relatively large, although the relative humidity is relatively high, the moisture content is relatively low, and it is difficult to get out of the air, but after the air is heated, the moisture content is constant, the air is The relative humidity drops rapidly, so the temperature and humidity of the room can be controlled by the system heating operation. At this time, the four-way valve is charged, the system operates according to the heating mode, the second heat exchanger in the room is turned off by the electromagnetic valve, the outdoor heat exchanger is the evaporator, and the first heat exchanger in the room is the condenser. In this mode, after the indoor air is heated by the first heat exchanger in the room, it is returned to the room through the second heat exchanger in the room without heat exchange. In this way, the temperature of the air rises and the humidity drops, thereby achieving control of the indoor temperature and humidity.


(5) Automatic defrost


When the system is operating in modes (1)-(3), the indoor first heat exchanger is an evaporator. When the surface temperature of the evaporator is lower than 0 °C, the relative humidity of the air entering the evaporator is large, and the moisture in the air may be The outer surface of the evaporator is frosted. When the frost reaches a certain thickness, the air side pressure loss increases, the air flow rate decreases, and the heat exchange effect is poor, and defrosting is required. At this time, the unit is operated in the heating and humidity control mode (?), the indoor first heat exchanger is used as a condenser, and the entry of the high-temperature refrigerant causes the frost to melt rapidly, and then restores the original operation mode.


When the system is operating in heating mode (4), the outdoor heat exchanger is an evaporator. When the outdoor air temperature is low and the humidity is high and the evaporator surface temperature is lower than 0 °C, the outer surface of the outdoor heat exchanger may also be frosted. After the frost reaches a certain thickness, the unit is operated in the temperature-controlled dehumidification mode (2), the outdoor heat exchanger acts as a condenser, the entry of the high-temperature refrigerant causes the frost to melt rapidly, and the indoor second heat exchanger also acts as a condenser to prevent being indoors. The air cooled by the first heat exchanger directly enters the room, and when the frost is completely removed, the heating and temperature regulation mode is restored.