Contact Us
- No.116, Changda Rd, Yuhang District, Hangzhou, Zhejiang, China
- eva@conloon.com
- +86-571-81600072
Industrial Duct Dehumidifier 50L
Ceiling mounted dehumidifier is widely used in swimming pool,underground parking to save place
Description
Industrial Duct Dehumidifier 50L
Product Parameters
Model | CLG-50 |
Maximum dehumidification | 50L/day (30℃ RH80%) |
Voltage | 220V~/50Hz/60Hz |
Maximum input current | 4.6A |
Maximum input power | 980W |
Circulation volume | 500m3/h |
Ambient temperature | 5-38℃ |
Static pressure | 70Pa |
Outer diameter of drainage | Φ14mm |
External controller | Box 86,the standard wiring length is 6 meters |
Air inlet and outlet | Front inlet and left outlet |
With or without filter | No |
Inlet and outlet air flanges | Φ188mm(outer diameter ) |
Shape volume (width x depth x height) | 418.5X655X391 |
Recommended apllied area: 40-80m2(height about 3m).
Display mode: Liquid crystal humidity RH10-90% is displayed randomly.
Humidity control: Microcomputer control, humidity 1%, free setting and control (the computer board is equipped with power failure memory function).
Frost function: Microcomputer intelligent control, automatic defrosting, low temperature applicable.
Compressor: International brand low noise reciprocating compressor, low noise, reliable operation.
Power supply: 220V power supply, with the compressor three-minute delay protection, sensor failure indication error code and other devices.
Cooling system: Adopting high efficiency copper clad aluminum sheet heat exchanger, the heat exchanger has compact structure, good pressure resistance and high heat exchange efficiency.
Wind machine design: The air volume is large, the friction is small, the noise is small, the service life is long.
Drainage way: continuous drainage with pipe.
Move mode: A mounting bracket is installed at the bottom (see the back figure).
Product Display
Installation of Ceiling Mounted Dehumidifier



Installation Instruction

Fresh Air Duct Dehumidifier
The fresh air duct dehumidifier is also called the fresh air system and the fresh air dehumidifier. It is a new type of indoor ventilation and exhaust equipment. It is an open circulation system that introduces outdoor fresh air and discharges indoor harmful gases, so that people do not need to open windows indoors. You can also enjoy the fresh air of nature, and you can also avoid the "air conditioning disease" and more effectively eliminate various bacteria and viruses in the room. It has the functions of purifying air, moisture-proof and dehumidification, ventilation and ventilation. It is the terminator of indoor air pollution in winter, which can guarantee your quality of life and allow you to breathe fresh air when the fog is rampant.
The fresh air duct dehumidifier can reach the various rooms in the room through the pipeline. Dehumidification or ventilation can be performed according to the needs of the season and the weather, which can achieve central dehumidification, ventilation, and can be automatically adjusted according to the humidity value set by the user, so that the indoor air is fresh while achieving the right humidity. Make sure that you are exposed to the freshest air at all times.
Knowledge about Duct Dehumidifier
First, duct dehumidifier application
The duct dehumidifier is used in villas, hotels, office buildings, laboratories, underground parking lots, etc. Concealed installation, beautiful, practical, and save space.
At the same time, it can be applied to large warehouses and workshops without vacant places, so as to avoid heavy losses caused by moisture and mildew. Concealed installation, beautiful, practical, and save space.
Second, the working principle of duct dehumidifier
The duct dehumidifier draws humid air into the machine through the fan, and cools the evaporator to below the dew point by compressor refrigeration. The humid air condenses into water on the surface through the evaporator, collects into the water tray, and flows into the water tank. The dry air passes through. The reheating of the condenser is discharged from the air outlet, so that the continuous circulation reduces the humidity in the room.
Third, how to choose duct dehumidifier
1. Measure the space volume used, area x height (converted to 2.6 meters for use after measurement).
2. Consider the humidity range you need. The general space humidity range is about 60%, and the humidity range for valuables is about 50%.
3. The general space humidity range is configured according to the use area of 1-1.2 times per liter of dehumidification;
The storage humidity range of valuables is configured according to the use area of 0.6-0.8 times per liter of dehumidification;
Of course, it is also possible to appropriately enlarge the ratio of the area used, but the larger the area used, the longer the time required for dehumidification.
4. For use in special environments, please consult the sales consultant for the specific use plan.
Fourth, duct dehumidifier use precautions
1. The optimal operating temperature range of the dehumidifier is 15 °C ~ 38 °C.
2. When the dehumidifier is used, the doors and windows should be closed as much as possible to achieve better dehumidification effect.
3. The dehumidifier should be placed in the center of the room to achieve uniform dehumidification, and there should be no obstructions in the inlet and outlet.
4. The dehumidifier should be placed flat during use, and should not be tilted or crossed to avoid machine malfunction or abnormal noise.
5. The dehumidifier should be placed in a space that cannot be placed in corrosive gas and high dust. It is used for corrosive gases. Please choose a dehumidifier with anti-corrosion function. For high dust environment, please clean or replace it frequently. Filter the net and clean the dust in both machines to ensure dehumidification performance.
6. After the dehumidifier has been transported, please let it sit for 4-6 hours before turning it on.
Five, duct dehumidifier maintenance method
1. When there is adhesive or dust on the surface of the machine, it can be washed with soapy water to avoid gasoline, petroleum spirit, solvent, etc., to avoid paint or discoloration.
2, the filter should be cleaned regularly (about two weeks) to maintain the machine dehumidification, dust removal efficiency and longevity, while avoiding bacterial growth.
3, the two should be regularly washed with water, according to the dust situation, about once every two months to ensure dehumidification performance.
4. When not using the machine for a long time, please unplug the power cord and press the steps 1, 2 and 3 to clean the machine.
Contact Us
If you have any questions or inquiry, please feel freely to contact us at: sales@conloon.com
Hot Tags: industrial duct dehumidifier 50lChina, manufacturers, suppliers, factory, wholesale