Detailed Parameters:
| Model | DH-5168C | |
| Humidity Removal | 168L/D or 7L/H | |
| Power Source | 380V/50HZ | |
| Rated Power Input | 3.2KW | |
| Power Current | 6.2A | |
| Work Temperature | 5-38℃ | |
| Circulating Air | 1600M3/h | |
| Refrigerant | R22/R407C | |
| Net Weight | 108Kg | |
| Gross Weight | 118Kg | |
| Applying Space | 150~200m2 | |
| Product Dimension | 405x605x1620mm | |
| Packing Dimension | 485x655x1680mm | |
| Loading Qty | 33pcs/20ft | |
| Production period | 10 days | |
| Warranty | 1 year | |
Product Photos:
Why is the effect of dehumidifiers in winter far less than that of summer? What are the factors that affect the dehumidification effect of dehumidifiers?
The use of dehumidifiers can help you effectively reduce the humidity of indoor air, but many users find that the use of winter dehumidifiers is often far less than summer. So what is the cause of the above phenomenon, and what are the factors that affect the dehumidification effect of the dehumidifier? We will give you a detailed analysis of the above problems, hoping to help you better operate and use dehumidifiers in winter! If you have any doubts, we welcome your inquiries!
Knowledge point 1: Winter dehumidifiers use less than summer reasons
In winter, the temperature is low, the air is relatively dry, and the indoor air moisture content is relatively low. At this time, the dehumidification effect is not as good as that in summer, the water extracted is also significantly reduced compared with other seasons; and the dehumidifier is operated at low temperature, which is easy to knot. If the frost is frozen, it needs to be defrosted before dehumidification, which will reduce the dehumidification time. If the temperature is lower than 5 degrees, the dehumidifier may not be able to pump out water.
Knowledge point 2: Factors affecting the dehumidification effect of the dehumidifier
Incorrect settings - the dehumidifier has a set value before use, ie indoor target humidity, but the actual dehumidification capacity of the dehumidifier is somewhat different from the target value of 60%, especially in winter. Therefore, when using a dehumidifier, the dehumidification value of the dehumidifier should be adjusted according to the seasonal changes, and the correct value should be set.
Fault - When the dehumidifier fails, the dehumidification effect is definitely not as good as normal. Common faults of the dehumidifier include: damage to the humidity sensor, damage to the humidity sensor, failure of the compressor to start, and leakage of the dehumidifier.